Inspection Item | Technical Requirements | Inspection Method |
Appearance | Milky white liquid | Inspection Method: Observe the color of the liquid visually. |
Solid Content | 60% | Inspection Tools: Watch glass (with a diameter of 7.5cm), oven, high-precision electronic scale. Inspection Method: Stir the test liquid evenly, take a sample of 2.0g ± 0.5g in a surface dish that has been weighed, weigh it, gently rotate the surface dish, and cover the bottom of the surface dish with the sample. Put it in an 80℃ oven for about 2 hours, weigh it multiple times during heating, make the difference between the two weighings less than 0.005g, and obtain the weight of the solid. Conduct 2 parallel experiments and take the average value. |
PH | 7~9 | Inspection Tools: Electronic PH Meter. Inspection Method: Use an electronic pH meter that has been calibrated in a calibration solution to measure the sample taken out. |
Viscosity | 1200-1400cP | Inspection Tools: Brookfield viscometer,5# rotor. Inspection Method: Put the sample into a large caliber beaker or bottle, select the 5# rotor for installation and debugging, immerse the rotor in the sample until the mark, select the speed of 100RPM, and measure the viscosity value. |
Adhesive force | Good | Inspection Method: Cut out a small piece of carpet, smooth the carpet, apply the glue evenly on the back of the carpet according to the glue amount of 2.0-2.4kg/m3, and put it in the oven to dry. Pull the dried carpet by hand to see if any fur will fall off. |